ENERGY-Matched Heart-Rate Sensing Schedules for Pre-Symptomatic Infection Detection on Low-Cost Wearables

Authors

  • Hassan Jalal International School Lahore, Lahore, Pakistan
  • M.Usman Riaz Superior University, Lahore, Pakistan

DOI:

https://doi.org/10.54938/ijemd-ss.2026.05.6.887

Keywords:

wearable sensing, heart rate, infection detection, pre-symptomatic warning, energy-aware sensing, duty cycling, resting heart rate, smartwatch

Abstract

Most wearable infection-detection studies have assumed that more sensing is better, and focused on deviations in resting heart rate preceding self-reported symptoms; however, not much consideration has been given to when sensing is needed when there is a limited budget for the amount of energy the device can expend. This study asks: Is there a difference in pre-symptomatic warning performance when the timing of the heart-rate acquisition is considered in addition to the amount of sensing? Two publicly released data sets (Stanford Phase 1 and Stanford Phase 2) were re-analyzed using a preregistered causal pipeline. The final frozen base cohort included 38 participants; 30 contributed to the primary paired comparison after arm-specific calibration requirements. On the primary, modelled-energy budget (E3), sparse schedules were employed with 7 acquisition bursts per day of 10 minutes each. The confirmatory comparison tested nocturnally sensing (S3) against uniform block (S2) through the personalized time-of-day-normalized resting-heart-rate detector, with an identical alert burden (no more than two alert-days/person-month) and with a hierarchical paired endpoint of detection and warning time. S3 did not outperform S2: W/L/T = 8/12/10, θ = 0.433 (95% BCa CI 0.300-0.583), exact two-sided p = 0.5034. Detection rate was 63.3% for S3 and 66.7% for S2 and median warning time was 13 and 14 days respectively for the detected cases. Due to H1 failure, the fixed-sequence gate was closed and the remaining schedule comparisons were estimation-only. For all sensitivity analyses reported in H1, θ was kept at or below 0.5. These results do not demonstrate equality, but they do not offer any evidence that heart-rate acquisition focused at night is superior to an energy-matched uniform heart-rate acquisition schedule in warning about infection prior to symptoms onset in this sample. The study presents a framework for evaluation of sensing placement, alert burden, missingness and modeled device energy that is reproducible and suggests the need for larger prospective validation and measured hardware-energy experiments.

Downloads

Download data is not yet available.

References

[1] Alavi, A., Bogu, G. K., Wang, M., Rangan, E. S., Brooks, A. W., Wang, Q., Higgs, E., Celli, A., Mishra, T., et al. (2022). Real-time alerting system for COVID-19 and other stress events using wearable data. Nature Medicine, 28, 175–184. https://doi.org/10.1038/s41591-021-01593-2

[2] Banerjee, T., & Veeravalli, V. V. (2012). Data-efficient quickest change detection with on-off observation control. Sequential Analysis, 31(1), 40–77. https://doi.org/10.1080/07474946.2012.651981

[3] Cleary, J. L., Fang, Y., Sen, S., & Wu, Z. (2022). A caveat to using wearable sensor data for COVID-19 detection: The role of behavioural change after receipt of test results. PLOS ONE, 17(12), Article e0277350. https://doi.org/10.1371/journal.pone.0277350

[4] Dheman, K., Giordano, M., Thomas, C., Schilk, P., & Magno, M. (2024). i-CardiAx: Wearable IoT-driven system for early sepsis detection through long-term vital sign monitoring. In Proceedings of the 2024 IEEE/ACM Ninth International Conference on Internet-of-Things Design and Implementation (IoTDI) (pp. 97–109). https://doi.org/10.1109/IoTDI61053.2024.00013

[5] gireeshkbogu. (n.d.). AnomalyDetect [GitHub repository]. https://github.com/gireeshkbogu/AnomalyDetect

[6] Mishra, T., Wang, M., Metwally, A. A., Bogu, G. K., Brooks, A. W., Bahmani, A., Alavi, A., et al. (2020). Pre-symptomatic detection of COVID-19 from smartwatch data. Nature Biomedical Engineering, 4, 1208–1220. https://doi.org/10.1038/s41551-020-00640-6

[7] mwgrassgreen. (n.d.-a). Alarm [GitHub repository]. https://github.com/mwgrassgreen/Alarm

[8] mwgrassgreen. (n.d.-b). WearableDetection [GitHub repository]. https://github.com/mwgrassgreen/WearableDetection

[9] Quer, G., Radin, J. M., Gadaleta, M., Baca-Motes, K., Ariniello, L., Ramos, E., Kheterpal, V., Topol, E. J., & Steinhubl, S. R. (2021). Wearable sensor data and self-reported symptoms for COVID-19 detection. Nature Medicine, 27, 73–77. https://doi.org/10.1038/s41591-020-1123-x

[10] Radin, J. M., Wineinger, N. E., Topol, E. J., & Steinhubl, S. R. (2020). Harnessing wearable device data to improve state-level real-time surveillance of influenza-like illness in the USA: A population-based study. The Lancet Digital Health, 2(2), e85–e93. https://doi.org/10.1016/S2589-7500(19)30222-5

[11] Shea, S. A., Scheer, F. A. J. L., Gumz, M. L., Eikenberry, S. A., Qian, J., Thosar, S. S., Sole, M. J., & Martino, T. A. (2026). Unlocking the potential of circadian biology for cardiovascular health. Physiological Reviews, 106(3), 1195–1262. https://doi.org/10.1152/physrev.00015.2025

[12] Speed, C., Arneil, T., Harle, R., Wilson, A., Karthikesalingam, A., McConnell, M., & Phillips, J. (2023). Measure by measure: Resting heart rate across the 24-hour cycle. PLOS Digital Health, 2(4), Article e0000236. https://doi.org/10.1371/journal.pdig.0000236

[13] StanfordBioinformatics. (n.d.). Wearable-infection [GitHub repository]. https://github.com/StanfordBioinformatics/wearable-infection

[14] Tognotti, A., Otesteanu, C. F., Anceschi, L., & Menon, C. (2026). Baseline normalisation choices inflate classification performance in wearable health monitoring: Quantification and mitigation strategies. Frontiers in Digital Health, 8, Article 1827279. https://doi.org/10.3389/fdgth.2026.1827279

[15] Wallner, J., Berbuir, S., Birner, L., Dendorfer, A., Panthi, B., Rahnsch, B., Muma, J., Munga, S., Obor, D., Bärnighausen, T., et al. (2026). Overcoming data loss in wearable disease detection with GAN-based imputation. npj Digital Medicine, 9, Article 275. https://doi.org/10.1038/s41746-026-02518-4